Skip to content
Call 085 - 3016 440 and get in touch

Kstar

KSTAR BluePulse BC107DE2 CATL

Product code 06-111Manufacturer code 1035G0045

  • 107,52 kWhCapacity
  • 6000 (80% EOL) / 8000 (70% EOL)Cycles
  • 90% (recommended)DoD

Overview

The KSTAR BC107DE2 is the 107.52 kWh outdoor battery cabinet of the BluePulse series, in an enclosure of 1062 × 2083 × 1371 mm. Six 17.92 kWh LFP modules with 280 Ah cells form one 384 V cluster (operating range 342–432 V). Charging and discharging run at up to 0.5C with a rated current of 140 A; actual power is limited by the connected PCS. Its own BMS and EMS unit control the cabinet, an air conditioner cools or heats, and fire safety comes from carbon monoxide detection, a sound and light alarm, an exhaust fan, an explosion vent and a fire-water inlet. At about 1430 kg, IP54 and corrosion class C4 it is installed outdoors at -30 to +50 °C. Communication via Ethernet, CAN and RS485. KSTAR pairs the BC107DE2 with a PCS from the KAC50DP2 or KAC80-125DP2 series.

Specifications

General

Product code
06-111
Manufacturer code
1035G0045
Type
Outdoor C&I battery cabinet (LFP) with EMS unit
Series
BluePulse
Model
BC107DE2
Segment
Commercial

Power and efficiency

Capacity
107,52 kWh
Charge power
0,5C (140 A), limited by the PCS
Chemistry
LFP
Cell type
LFP 280 Ah
Cycles
6000 (80% EOL) / 800070% EOL
DoD
90%recommended

Electrical

Communication
Ethernet / CAN / RS485Modbus TCP/IP

Mechanical

Dimensions
1062 × 2083 × 1371 mm
Weight
ca. 1430 kg
IP rating
IP54

Warranty

Warranty
5 years product / 10 years performance70% usable energy

Questions

The short ones are here. For anything else, ask below.

The KSTAR BC107DE2 is the 107.52 kWh outdoor battery cabinet of the BluePulse series, in an enclosure of 1062 × 2083 × 1371 mm. Six 17.92 kWh LFP modules with 280 Ah cells form one 384 V cluster (operating range 342–432 V). Charging and discharging run at up to 0.5C with a rated current of 140 A; actual power is limited by the connected PCS. Its own BMS and EMS unit control the cabinet, an air conditioner cools or heats, and fire safety comes from carbon monoxide detection, a sound and light alarm, an exhaust fan, an explosion vent and a fire-water inlet. At about 1430 kg, IP54 and corrosion class C4 it is installed outdoors at -30 to +50 °C. Communication via Ethernet, CAN and RS485. KSTAR pairs the BC107DE2 with a PCS from the KAC50DP2 or KAC80-125DP2 series.

KSTAR BluePulse BC107DE2 CATL is 107,52 kWh.

Need help choosing?

Our advisors put together the right mix of panels, inverters and storage for your project.

Book a call